Zum Hauptinhalt springen Zur Suche springen Zur Hauptnavigation springen

CL-211-E PM2.5/CO/Temperature/Humidity Data Logger, RS-485 & Ethernet PoE

Produktinformationen "CL-211-E PM2.5/CO/Temperature/Humidity Data Logger, RS-485 & Ethernet PoE"

The CL-211-E CR is a data logger module that records PM2.5, CO, temperature, humidity and dew point readings, each stamped with date and time. It stores up to 450,000 downloadable records, giving engineers an auditable history of indoor air or storage conditions.

Connectivity is provided by an RS-485 port and an Ethernet port with PoE, supporting DCON, Modbus RTU, Modbus TCP and MQTT. Live data can be viewed across the same local network using the free Windows software or the iOS and Android apps, and the module can be integrated into existing HMI or SCADA systems. An onboard relay output (1 x Form A, SPST) can drive an alarm or an indoor air quality control device.

Typical deployments include food and pharmaceutical transport, HACCP-controlled food and beverage sites, building and energy management, warehouses, museums and archives, and monitoring of indoor or underground car parks. The module is rated IP20 for ceiling or wall mounting, with an operating temperature of 0 ~ 50°C.

Applications

  • Transportation of food or pharmaceuticals
  • Food and beverage industry (HACCP)
  • Blood stations and pharmacies
  • Building and energy management
  • Warehouse management
  • Museums, archives and galleries
  • Indoor or underground parking lot air quality monitoring
Product type: Data logger module
Interface: Ethernet, RS-485
Protocol: DCON, Modbus RTU, Modbus TCP, MQTT
Ports: 2
PoE: Yes
Power input: +12 ~ +48 VDC
Operating temperature: 0 ~ 50°C
Mounting: Ceiling/Wall

Technische Daten

System
AlarmPM2.5/RH/Temperature
Real Time ClockYes
Data LoggerYes, up to 450,000 records
Temperature Measurement
Range-10 ~ +50°C
Resolution0.1°C
Accuracy±0.6°C
Humidity Measurement
Range0 ~ 100% RH, Non-condensing
Resolution0.1% RH, Non-condensing
Accuracy±5% RH, Non-condensing
Dew Point
RangeCalculated using temperature and relative humidity
Resolution0.1°C
CO Measurement
Range0 to 1000 ppm (Electrochemical)
Resolution1 ppm
Accuracy±5% of measured value
Response Time30 seconds
Warm-up Time5 minutes
PM2.5 Measurement
Range0 ~ 400 μg/m3
Resolution1μg/m3
Response Time<= 1 min.
Relay Output
Channels1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports1 x RS-485
1 x Ethernet
ProtocolDCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Power
ConsumptionNon-PoE: 2.66 W (Max.)
PoE: 2.73 W (Max.)
Powered from Terminal Block+12 ~ +48 VDC
Mechanical
Dimensions (mm)Ø 150 x 53 (Ø x H)
InstallationCeiling Mounting/Wall Mounting
Ingress Protection RatingIP20
Environment
Operating Temperature0 ~ 50°C
Storage Temperature-30 ~ +75°C
Humidity10 ~ 90% RH, Non-condensing

Technische Daten laut Hersteller. Änderungen vorbehalten.