I-2533CS-60 CAN to Single-Mode Fibre Bridge, 60 km SC Connector

Produktinformationen "I-2533CS-60 CAN to Single-Mode Fibre Bridge, 60 km SC Connector"

The I-2533CS-60 extends a CAN bus over single-mode fibre. It converts the electrical CAN signal to a 1310 nm optical link on an SC connector, so two CAN networks can be joined over up to 60 km. Because the link is independent of the CAN baud rate, the distance is not reduced when a faster rate is used, and a fault on one CAN network does not stop the other from operating.

Each unit uses an NXP TJA1042 transceiver and supports CAN 2.0A and CAN 2.0B to ISO 11898-2. The baud rate is set with a rotary switch or can be user-defined, and a built-in switch enables the 120 Ω terminal resistor. Fibre broken-line detection and a utility tool for CAN message filter configuration help with commissioning and fault finding.

  • Suits point-to-point CAN links where copper cabling would be too long or electrically unsuitable
  • Fibre link uses 8.3/125, 8.7/125, 9/125 or 10/125 μm cable, with 9/125 μm recommended for 60 km
  • Mounts on DIN-rail with a removable terminal block

Applications

  • Connecting two CAN bus systems over long single-mode fibre runs
  • Remotely operated underwater vehicle (ROV) systems
Product type: CAN to single-mode fibre bridge
Interface: CAN, SC single-mode fibre
Protocol: CAN 2.0A/2.0B
Ports: 1 CAN, 1 SC fibre, 1 RS-232 utility
Isolation: 2500 Vrms (CAN side)
Power input: +10 VDC ~ +30 VDC
Operating temperature: -25 ~ +75 °C
Mounting: DIN-rail
Housing: Plastic

Technische Daten

LED Indicators
Status1 x Power
3 x CAN status
2 x Fiber status
COM Ports
Ports1 x RS-232 (Utility Port)
Fiber
PortsSingle-Mode; SC Duplex connector x 1; 100 Base-FX
Fiber Cable8.3/125, 8.7/125, 9/125 or 10/125 μm
Wavelength1310 nm
TX Output-5 dBm Min. , 0 dBm Max.
Transmission Distance60 km (9/125 μm recommended)
RX Sensitivity-35 dBm Max.
RX Overload-5 dBm Max.
Budget30 dBm
Propagation Delay190 us (*Note1)
CAN
Ports1
SpecificationISO 11898-2, CAN 2.0A and CAN 2.0B
Baud Rate10 k ~ 1 M bps
Isolation2500 Vrms on the CAN side
Terminal ResistorSwitch for 120Ω terminal resistor
FilterYes
Power
Input Range+10 VDC ~ +30 VDC
Consumption3 W
Mechanical
CasingPlastic
Dimensions (mm)33 x 126 x 101 (W x L x H)
InstallationDIN-Rail
Environment
Operating Temperature-25 ~ +75 °C
Storage Temperature-30 ~ +80 °C
Humidity10 ~ 90% RH, Non-condensing